- This sampling system is completely fabricated in AISI 316 rated stainless steel
- The TRI CLAMP connection simplifies all the cleaning/sterilization operations
- The risk of contamination associated with operator activities is reduced
- The Remote Aspirating Funnel can be manipulated in multiple directions
- The Remote Funnel System is fully sterilizable
TRIO.BAS™
Aspirating Funnel System Tri Clamp
Remote Stainless Steel Tri Clamp Aspirating Funnel System
Use and application
Code | TRIO.BAS REMOTE S/S FUNNEL TRI CLAMP (*) |
---|---|
181 | REMOTE FUNNEL SYSTEM – s/s aspirating funnel end clamp with s/s aspirating bell and tube end clamp to connect the system to an Air Sampler |
193 | s/s tri clamp with silicone gasket |
194 | s/s tube with 2 clamps end - 10 cm length |
190 | s/s tube with 2 clamps end - 20 cm length |
189 | s/s tube with 2 clamps end - 50 cm length |
186 | gasket for TRI CLAMP 187 s/s TRI CLAMP closing cap |
188 | s/s elbow short tube 90° with 2 clamps end - size wheelbase 40 mm |
195 | s/s elbow 90° tube with 2 clamps end - size wheelbase 88,90 mm, radius 25,40 mm |
198 | s/s wall connection with 2 clamps end |
(*) different sizes on request
IN-REST holder
Operators, and their activities, represent the greatest risk of contamination inside cleanrooms. Operators must work under stringent conditions; required to wear special overalls, gloves, facemasks, and eye masks. For these reasons, it is advisable to create the best possible working conditions. Air sampling with microbiological samplers is a complex and delicate operation, whether using an instrument with a single aspirating head, or an instrument with more than one aspirating head. To facilitate operations and avoid errors and risks of contamination during the sampling phase, the TRIO.BAS IN-REST is particularly useful as a temporary support for culture media plates and/or lids, and instrument sampling heads.
FEATURES
- Built in AISI 316 stainless steel
- Wedge shape inclined at 150°
- Two-sided Support
- Usable for Petri dishes, Contact plates and aspirating heads
- A single hole on one side, and two holes on the other side, facilitate identification of plates and heads
ID PACK CODE
Code | |
---|---|
180 | IN-REST holder - Stainless steel AISI 316 - size 90x120x105H mm - weight 127 gr. |
GLP EASY RACK
Cleanroom Stainless Steel Rack with handle for stacking, storing, and transporting culture plates (Petri or Contact plate). They are used to maintain the distance inside the incubator according the GLP* (Good Laboratory Practice).
DETAILS
- They can be refrigerated, incubated and autoclaved
- Each rack can hold up to 11 Petri dishes, or 15 Contact plates
- A wide front opening permits easy access but prevents dishes from sliding out
- The same rack can be adjusted for Petri or Contact plate
- Avoids all risk of accident during loading and transport to the incubator for staff bio-hazard safety
- The weight of only 280 gr. make it light and easy to carry
- The small size allows to maximize the space inside the incubator
- Racks are fully autoclavable
*ISO Standard and GPL request that inside the incubator the culture plates are stacked not more than six and at a distance of 2 cm.
ID PACK CODE
Code | |
---|---|
175 | GLP EASY RACK AISI 316 Petri - capacity up 11 Petri dish 90 mm. size: diam. 110x215h mm. Contact - capacity up 15 Contact plate 55mm. size: diam. 110x215h mm. |
CLEANROOM BAG
Sterile bags ideal for safely containing and transporting Petri dishes, Contact plates, Swabs, or other objects, outside of the cleanroom:
- Sterility Traceability.
- Triple-wrapped and individually sealed to ensure sterility.
- Beta or Gamma sterilization certificate available.
- Color is easy to identify in the cleanroom.
- Write-on oversized area to identify sample contents suitable for use with permanent markers.
- Self-adhesive flap closure prevents contamination after samples are placed inside of the bag.
- Included an easy-open thear line which guarantees the sterility of the single bag.
- The elongated, flat bag design facilitates stacking of multiple bags, easy reading of bag contents, and allows plate lids to stay secured inside the bag during handling.
ID PACK CODE
Code | |
---|---|
381 | CLEANROOM BAG - plain sampling bag - polyethylene film - sterilized by irradiation Gamma or Beta ray - sizes: 40x13 cm. - 15 x bag - 150 x box. |
Sterile Daily Shift Aspirating Head for Contact plate
The sterile Daily Shift aspirating heads (DSH - sterile Daily Shift Head) avoid the sterilization process necessary for stainless steel aspirating heads.
The sterilization is proven by an official certificate. This document is requested by regulatory authorities.
The triple irradiated sterile packaging allows the users to always have aspirating heads ready for use.
ID PACK CODE
Code | |
---|---|
340 | Sterile Daily Shift Aspirating Head for Contact plate 55 mm - size 100 diameter X 14 H mm - weight 48 gr - in triple sterile bag (20 x box) - size 375X265X220H mm - weight 1,3 kg. |
Sterile Daily Shift Aspirating Head for Petri
The sterile Daily Shift aspirating heads (DSH - sterile Daily Shift Head) avoid the sterilization process necessary for stainless steel aspirating heads.
The sterilization is proven by an official certificate. This document is requested by regulatory authorities.
The triple irradiated sterile packaging allows the users to always have aspirating heads ready for use.
ID PACK CODE
Code | |
---|---|
341 | Sterile Daily Shift Aspirating Head for Petri 90 mm plate - size 102 diameter X 35 H mm - weight 52 gr - in triple sterile bag (20 x box) - size 375X265X220H mm - weight 1,4 kg. |